Numeric Display#

At a Glance

Parameters: Up to 150
Layout: Auto-sizing grid
Key Features: Colour thresholds, hex formatting, status indicators
Best For: Dashboards, live monitoring, quick inspection

The Numeric Display shows instant numeric readouts for up to 150 parameters at the cursor position. Text auto-sizes to fit the display window, and colours can reflect warning/critical thresholds. Double-click a value to edit that parameter's properties.

Numeric Display

When to Use Numeric Display#

📡 Live monitoring: Watch current values during recording

📊 Dashboard creation: Build custom parameter dashboards

🔍 Quick inspection: Check exact values at any cursor position

🚥 Status monitoring: Use colour thresholds to highlight issues

↔ Parameter comparison: View multiple related parameters together

Adding a Numeric Display#

To add a Numeric Display to a page, choose one of the following methods:

  • Toolbar: Click the Numeric Display button on the Display Toolbar.
  • Menu: Go to File > New > Display and select Numeric Display.
  • Shortcut: Press Ctrl+Q twice to open the Quick Access Assistant, type "Numeric", and select New Numeric Display.

Once added, use the Parameter Browser to add parameters and configure the display as needed.

Display Anatomy#

The Numeric Display shows a grid of parameters with:

  • Parameter name (optional)
  • Current value (at cursor position)
  • Units (optional)
  • Colour highlighting based on thresholds

Text size automatically adjusts to fit the available space.

Key Features#

Auto-Sizing Layout#

The display automatically:

  • Calculates optimal text size based on window size
  • Arranges parameters in a grid
  • Adjusts when you resize the window
  • Fills available space efficiently

You can override auto-sizing with fixed font size if preferred.

Colour Thresholds#

Parameters can show different colours based on their values:

Normal

Default text colour (typically white)

Warning

Uses Warning Colour (default blue) when a value goes outside its warning limits

Critical

Uses Critical Colour (default red) when a value goes outside its critical limits

Configuration

Set warning and critical limits for each parameter in the Limits section of the Parameter Properties panel, and turn on Show Warning Limits or Show Critical Limits. Parameters with these options off are never coloured.

Flexible Formatting#

Control what's displayed for each parameter:

  • Show/hide parameter name
  • Show/hide description
  • Show/hide numeric value
  • Show/hide units
  • Show/hide a + sign on positive values (Show Signs), so the sign of a value is never ambiguous
  • Show/hide status indicator

Parameters with a text conversion show the lookup text instead of the raw number. Parameters whose units are ddmmyy.hhmm are shown as a date and time.

Status Indicators#

Each indicator is a separate option in Display Properties, and all except Show Status Indicator are off by default:

  • Show Up Indicator: arrow when the value is above the last displayed value
  • Show Down Indicator: arrow when the value is below the last displayed value
  • Show Warning Indicator: icon when the value is in its warning range
  • Show Critical Indicator: icon when the value is in its critical range
  • Show Status Indicator: sample status. = means the cursor is exactly on a sample, ? means a default value. Between samples, the held value is shown with no indicator.

Hex Formatting#

For parameters displayed in hexadecimal:

  • Show "0x" for Hex Values shows or hides the 0x prefix (on by default)
  • Configurable uppercase/lowercase
  • Full hex formatting control

Grid Overlay#

Optional grid lines between parameters:

  • Show/hide grid
  • Custom grid colour
  • Adjustable padding around items
  • Column spacing control

Display Properties#

Press D with the display selected to open Display Properties.

Text Formatting#

Font Name: Choose from available system fonts (default Segoe UI)

Font Size:

  • Auto: Automatically scales to fit window (recommended)
  • Use Fixed Font Size with Fixed Font Size: Specify exact point size (default 12)

Alignment - Text:

  • Name alignment (Left, Right)
  • Value alignment (Left, Right)

Displayed Items:

  • Show Name
  • Show Description (off by default)
  • Show Value
  • Show Units
  • Show Signs (off by default)
  • Show Status Indicator
  • Show Up Indicator, Show Down Indicator, Show Warning Indicator, Show Critical Indicator (off by default)
  • Show "0x" for Hex Values

Colour Options#

Colours - Text:

  • Use Single Colour with Text Single Colour: All parameters use the same text colour (on by default)
  • Turn Use Single Colour off so each parameter uses its own colour

Colours - Ranges (Critical and Warning):

  • Critical Colour and Warning Colour
  • Apply Critical Colour and Apply Warning Colour: Threshold colours affect text colour (on by default)

Colours - Background:

  • Background Colour: Overall display background colour
  • Apply Critical and Warning Colours: Threshold colours fill the row background, which is easier to see from a distance. Turn off Apply Critical Colour and Apply Warning Colour first.
  • Use Parameter Colour: Fills each row background with the parameter colour

Colours - Selected Items:

  • Foreground and Background for selected parameters
  • Use Parameter Foreground Colour: Selected item text uses the parameter colour

Note: Critical/warning colours can apply to text OR background, not both simultaneously. The same applies to the parameter colour. If you try to use both, the status bar shows a message and the change is not applied.

Grid and Layout#

  • Show Grid: Enable/disable grid lines between parameters
  • Grid Colour: Colour of grid lines
  • Column Padding: Space either side of the grid column lines
  • Item Padding: Space around each parameter
  • Internal Border: Padding inside the display area

Data Update#

  • Auto Refresh Rate (Hz): How often the display updates when data is panning automatically, for example in live. Choose 1, 2, 5, 10, 20 or 30 Hz (default 5 Hz).

Adding Parameters#

After creating a Numeric Display:

  1. Open Parameter Browser (P)
  2. Find the parameters you want to monitor
  3. Drag parameters onto the display, or
  4. Select parameters and Add to Display

You can add up to 150 parameters.

Editing Parameter Properties#

Double-click any parameter value to open its Parameter Properties panel where you can:

  • Change parameter colour
  • Set warning/critical thresholds
  • Adjust decimal places
  • Change display format (decimal, hex, scientific)
  • Set custom units
  • Enable/disable features per parameter

Working with Parameters#

Selecting Parameters#

  • Click a parameter to select it
  • Selected parameters show highlighted background
  • Ctrl+Click: Add to selection
  • Shift+Click: Select range

Reordering Parameters#

Drag parameters to reorder them within the grid.

Removing Parameters#

  • Select parameter(s)
  • Press Delete key

Copying Values#

Copy to Clipboard:

  • Right-click > Copy Selected Items to Clipboard (or Ctrl+C) copies the selected parameters. If nothing is selected, Ctrl+C copies all of them.
  • Right-click > Copy to Clipboard copies all parameters

Values are copied as tab-delimited text (name, value, units), suitable for pasting into Excel or other tools.

Snapshot Export#

Export current display values to file:

  1. Right-click display
  2. Select Snapshot to Data File

ATLAS writes a .txt file of comma-separated name, value and units to Documents\McLaren Applied Technologies\ATLAS 10\Snapshots, named after the display. The status bar shows the full path of the file.

Keyboard Shortcuts#

Key Action
D Display Properties
Delete Remove selected parameters
Ctrl+C Copy selected values (all values if nothing is selected)
Ctrl+A Select all parameters
↑/↓ Move the selection up or down

Example Configurations#

Create a clean monitoring dashboard:

  • Set Show Name: ON
  • Set Show Value: ON
  • Set Show Units: ON
  • Set Show Description: OFF
  • Enable Apply Critical Colour and Apply Warning Colour
  • Set appropriate thresholds

📊 Perfect for: Live monitoring stations

Show just the numbers:

  • Set Show Name: OFF
  • Set Show Value: ON
  • Set Show Units: OFF
  • Turn off Use Single Colour so each parameter uses its own colour
  • Disable Show Status Indicator
  • Hide grid for cleaner look

🔢 Perfect for: Dense parameter grids

Highlight issues immediately:

  • Turn off Apply Critical Colour and Apply Warning Colour
  • Enable Apply Critical and Warning Colours (Colours - Background)
  • Set Background Colour: Dark colour
  • Configure warning/critical thresholds
  • Enable Show Warning Indicator and Show Critical Indicator
  • Leave Use Fixed Font Size off so text scales to fit

🚥 Perfect for: Alert dashboards

Tips & Tricks#

Layout Optimization

✅ Dashboard creation: Use Numeric Display as main dashboard component

🎨 Colour coding: Set up threshold colours to instantly spot issues

🔄 Live monitoring: Auto Refresh Rate (Hz) goes up to 30 Hz; the default is 5 Hz

Data Display

🔢 Hex values: Great for displaying status words and bit fields

🔍 Quick check: Add Numeric Display temporarily to inspect specific values

🖥 Multi-monitor: Float Numeric Display on second monitor for live monitoring

📑 Parameter grouping: Group related parameters for easier monitoring

Troubleshooting#

Text too small to read?
  • Reduce number of parameters
  • Increase window size
  • Use fixed font size instead of auto
Text too large?
  • Add more parameters to fill space
  • Use fixed font size and reduce point size
Colours not showing?
  • Check warning/critical thresholds are configured in Parameter Properties
  • Verify Show Critical Limits or Show Warning Limits is on for the parameter
  • Verify Apply Critical Colour / Apply Warning Colour (text) or Apply Critical and Warning Colours (background) is enabled
  • Check text vs background colour application setting
Values not updating?
  • Check Auto Refresh Rate (Hz) is appropriate
  • Verify session is loaded and active
  • Check cursor is moving (if not live)
Parameter disappeared?

May have been deleted instead of hidden. Re-add from Parameter Browser.